• DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response
  • DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response
  • DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response
  • DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response
  • DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response
DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response

DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response

Product Details:

Place of Origin: China
Brand Name: Supmeter
Certification: CE
Model Number: dCX-61-BST106-B60[T]

Payment & Shipping Terms:

Minimum Order Quantity: 1pc
Price: negotiation
Packaging Details: carton
Delivery Time: 3workdays
Payment Terms: Western Union, T/T
Supply Ability: 10000pcs/month
Get Best Price Contact Now

Detail Information

Power Supply: DC24v Material: Steel
Verfication Accuracy: 0.02% Verification Accuracy: III
Max. Connection Number Of Loadcell: 4 Loadcells (350Ω) Communication Port: COM1:RS232; COM2:RS485
High Light:

programmable load cell controller

,

load cell indicator

Product Description

DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response

Rapid Dynamic Response Force Measuring Controller For DO Alarm Output , AO / Digit Transmission

 

Rapid Dynamic Response Force Measuring Controller

For [ Positive&Negative Direction Real-time Force Value Display]

       [DO Alarm Output , AO / Digit Transmission]

       [Peak Value Detection / Display Holding]

 

 

Technical Specification

  • Executing Standard
  • CMC GB/T 7724-2008PRC National Standard.
  • OMIL R76: 2006International Recommendation.
  • Accuracy Grade: III.
  • Verification Accuracy: 0.03%.
  • Static Force Measuring Accuracy: 0.2%~0.5%.

 

Display

  • 6+8 Red LED digital tubes for English character and digit display.
  • Force Value Display Range: -60,000~+60,000.
  • Force Capacity: Setting Range 1~60,000.
  • Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
  • Display Resolution: 1/60,000.
  • Force Value Unit: Optional kg, t, g, none.
  • Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
  • Display Refreshing Time: Setting Range 0.01~1.00s.

 

Kaypad

  • Model Panel-mounting: 4-key English keypad.
  • Model Explosion-proof: 6-key English keypad.
  • Menu&Shortcut mode operation with key tone.

 

Loadcell Interface

  • Excitation Voltage/Max. Current: DC9V/120mA [4-350Ω loadcells].
  • Signal Input Range: -22.5~+22.5mV.
  • Output Sensitivity of Loadcell: 1.0~2.5mV/V.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • Sampling Frequency: 3200Hz.
  • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  • Gain Drift: ±5ppm/℃.
  • Non-linearity: 0.005%FS.

Switch&Analog Signal Interface

  • 6 Normally Open Switch Inputs [DI].
  • 5 Normally Open Relay Switch Outputs [DO]: AC250V/DC24V, 1A.
  • 1 Optional&Definable Analog Signal Output: 4~20mA, Non-linearity: 0.05%FS.

Digital Communication Interface

  • COM1: RS232.
  • COM2: RS485.
  • Connectable: Host IPC/PLC and LED Remote Display.

Operating Specification

 Operating Voltage

  • Model Panel-mounting: DC24V±20%.
  • Model Explosion-proof: AC110~240V, 50/60Hz.

  Max. Power Consumption: 5W.

 

Outline Size and Weight

  • Model Explosion-proof: 256×290×166mm [W×H×D].
  • Model Explosion-proof: Approx. 9.2kg.

 

Operating Temperature: -25℃ to +45℃.

Storage Temperature: -30℃ to +60℃.

Relative Humidity: Max. 85%RH.

Application Environment of Model Explosion-proof

  • Explosion gas environment: Zone 1&2.
  • Classes of explosion gas mixture: IIA, IIB.
  • Temperature grades of explosion gas mixture: T1~T6.
  • Ex-mark: Ex d IIB T6 Gb.

Protection Level

Front Panel of Model Panel-mounting: IP65.

Model Explosion-proof: IP65.

   

 

 

Keypad Operation

     If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.

Menu Operation
Key Name Description
【MENU】

Enter Main Menu.

Exit.

【ENT】 Enter / Save / Alarm Acknowledge.
【◄】

Cursor shifts left.

Display the previous option.

【►】

Cursor shifts left.

Display the next option.

【▲】

Display the next interface or option.

Digit input: +1 ( 0~9 loop).

【▼】

Display the previous interface or option.

Digit input: -1 ( 0~9 loop).

Quick Operation

【MENU】

【Ñ】

*

  • Key-locking.
  • Key-unlocking.

【◄】

(【SET】)

Setpoint parameters setting.

【◄】

【ZERO】

【→0←】

*

  • [-ZEro-]: Zero Calibration with Power-down Protection.
  • [≡ZEro≡]: Zero Fine Adjustment without Power-down Protection.

【ENT】

(【CLS】)

*

Clear Screen: Clear the display value of Peak Hold Value.

*: Keep the key pressed for 2 seconds.

 

 

Rapid Dynamic Response Force Measuring Controller For DO Alarm Output , AO / Digit Transmission

 

DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response 0

 

Model Explosion-proof Operation Interface:

DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response 1

 

Installation:

DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response 2

 

 

 

 

Want to Know more details about this product
I am interested in DO Alarm Output Weighing Indicator Controller With Rapid Dynamic Response could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.