• Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System
  • Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System
  • Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System
  • Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System
Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System

Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System

Product Details:

Place of Origin: China
Brand Name: Supmeter
Certification: CE
Model Number: BST106-B60[R]

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Price: Negotiation
Packaging Details: 1pcs/box
Payment Terms: T/T, Western Union
Get Best Price Contact Now

Detail Information

Power Supply: DC24V DI: 4
DO: 2 Outline Size: 107*60*100mm
High Light:

electronic weight indicator

,

digital load controller

Product Description

Mini 3-D/3-CH Force Measuring Controller Electronic Weighing Indicator For 1-3 Channels Force Measuring System

 

     Technical Specification

  • Executing Standard
  • CMC GB/T 7724-2008PRC National Standard.
  • OMIL R76: 2006International Recommendation.
  • Accuracy Grade: III.
  • Verification Accuracy: 0.03%.
  • Static Force Measuring Accuracy: 0.2%~0.5%.
  • Display
  • 2×16 LCD display screen with white LED background for English/Digit display.
  • Channel X/Y/Z Force Value Display Range: -5000~+5000.
  • Resultant Force Display Range: 0~9999.
  • Channel X/Y/Z Force Capacity: Setting Range 1~5000.
  • Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
  • Display Resolution: 1/5000.
  • Force Value Unit: Optional kg, t, g, N, kN, none.
  • Decimal Point: Optional 0, 0.0, 0.00, 0.000.
  • Display Refreshing Time: Setting Range 0.01~1.00s.
  • Kaypad
  • 4-key keypad for shortcut operation.
  • Channel X/Y/Z Loadcell Interface
  • Excitation Voltage/Max. Current: DC5V/120mA [4-350Ω loadcells].
  • Signal Input Range: ±35mV.
  • Output Sensitivity of Loadcell: 1.0~7.0mV/V.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • Sampling Frequency: 1280Hz.
  • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  • Gain Drift: ±5ppm/℃.
  • Non-linearity: 0.005%FS.
  • Switch Signal Interface
  • 4 Normally Open Switch Inputs [DI].
  • 2 Transistor Switch Outputs [DO] for Real-time Resultant Force or Resultant Force Peak Value Upper/Lower Limit Alarm.
  • The Contact of Transistor Switches can be defined as ‘Normally Open’ or ‘Normally Closed’.
  • Contact Capacity of Transistor Switch: DC24V, 10mA.
  • Digital Communication Interface
  • COM1: Fixed configuration RS485&RS232. Free to select one of them via internal DIP switch.
  • Connectable: Host IPC/PLC and LED Remote Display.

  • Operating Specification
  • Operating Voltage: DC24V±20%.
  • Max. Power Consumption: 5W.
  • Outline Size: 107×60×100mm [W×H×D].
  • Panel Cut-out Size: 94×47 mm [W×H].
  • Operating Temperature: -10℃ to +40℃.
  • Storage Temperature: -30℃ to +60℃.
  • Relative Humidity: Max. 85%RH.
  • Protection Level of Front Panel: IP65.
  • Weight: Approx. 0.25kg.

 

     Pictures

 

Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System 0

Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System 1

    Data Display

Name Description Range Note
X

Channel X Real-time Force Value

or Peak Value.

-5000~+5000 Refer to Parameters [202]~[207].
Y

Channel Y Real-time Force Value

or Peak Value.

-5000~+5000
Z

Channel Z Real-time Force Value

or Peak Value.

-5000~+5000
[F] Real-time Resultant Force or Resultant Force Peak Value [Force Value Unit].

3-D Algorithm: F2 = X2 + Y2 + Z2

CUSUM Algorithm: F = X + Y + Z

 

        Alarm Sign

Sign Alarm Cause Solution
AD_ER ADC Failure. Replace the ADC module.
OV_AD Over ADC Range.

Force signal exceeds A/D conversion range.

1. Check if the loadcell is connected.

2. Check if the capacity of loadcell is too small.

3. Check if the loading force is too big.

OV_LD Force Value Overload Alarm.

Force Value>(Single-channel Force Capacity+9×Scale Division).

1. Check if the loadcell is connected.

2. Check if the capacity of loadcell is too small.

3. Check if the loading force is too big.

Refer to Parameter [102].

Resultant Force Overload Alarm.

Resultant Force>(Max. Resultant Force+9×Scale Division).

Refer to Parameter [102].

 

          State Indication

LED light Description
[RUN]

OFF: Real-time Force Value tracking display state.

ON: Peak Value Detecting Result holding display state [Peak Value Detecting Process Finished].

Blinking: Peak Value tracking display state [In Peak Value Detecting Process].

[AL1]

Real-time Resultant Force or Resultant Force Peak Value Upper Limit Alarm.

Refer to Parameters [200]&[202].

[AL2]

Real-time Resultant Force or Resultant Force Peak Value Lower Limit Alarm.

Refer to Parameters [201]&[202].

 

       

 

 

 

 

 

 

 

 

 

         Installation

Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System 2

Want to Know more details about this product
I am interested in Mini 3-D/3-CH Digital Weight Indicator For 1-3 Channels Force Measuring System could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.